French Italian Dutch Spanish Danish German Russian Japanese Korean Simplified Chinese    HOME      COMPANY     PRODUCTS     CATEGORY LIST     WHAT'S NEW!     INFO CENTER     CONTACT US
PRODUCTS
 
   Emergency and Clinics
  Accessories
  Cables/Holter/Electrodes
  ECG Machine
  ECG Series
  Electrosurgical unit
  Fetal Doppler
  Fetal Monitor
  OEM Modules
  Patient Monitor
  Phantoms / Tool Kit
  Pulse Oximeter
  SpO2 Sensors solution
  Testing Measuring Equipme
Category Descriptions

BEST SELLERS
SmartSat Pulse Oximetry Analyzer
Item No.: SmartSat
$0.00
HandHeld NIBP Simulator & Digital Manometer
Item No.: Handheld AccuPulse
$0.00    $0.00
OEM ETCO2 MODULE (End-tidal CO2) CO2 Module Model C200 for measuring Respiratory Carbon Dioxide CO2 Sensor
Item No.: MONM-C200
Patient Monitor MGW6012
Item No.: PMKM-MGW6012
 

Item Details   ITEM DETAILS  

MAMMOGRAPHY BR3D PHANTOM MODEL 020

The Model 020 BR3D Mammography Phantom was designed to assess detectability of various size lesions within a tissue equivalent, complex, heterogeneous background. This phantom provides more realistic challenges for standard screen and FFDM mammography systems as well as Tomosynthesis and breast Computed Tomography.
MAMMOGRAPHY BR3D PHANTOM MODEL 020
Model Number: Model 020
GOLDWEI Item No.: MMCS-020
 

Mammography
BR3D Phantom

For Tomosynthesis
and Breast CTk

Model 020


Benefits
• Tests Tomosynthesis and Breast Computed Tomography
• More representative than standard homogenous phantoms
• Complex background provides greater challenge for target
detection
• Slab configurations provides range of thicknesses with or
without targets


The CIRS Model 020 BR3D Mammography Phantom was designed to assess detectability of various size lesions within a tissue equivalent, complex, heterogeneous background. This phantom provides more realistic challenges for standard screen and FFDM mammography systems as well as Tomosynthesis and breast Computed Tomography.

The phantom consists of a set
of six (6) slabs made of heterogeneous breast
equivalent material that exhibits characteristics of real breast tissue and demonstrates how underlying targets can be obscured by varying glandularity.

Each slab contains two tissue equivalent materials mimicking 100% adipose and gland tissues “swirled” together in a approximate 50/50 ratio by weight. One of the slabs contains an assortment of micro-calcifications, fibrils and masses.

Each semicircular shaped slab measures 100 (H) x 180 (L) x 10 mm (T). Each slab, with its unique swirl pattern, provides varying backgrounds when arranged in multiple combinations and thicknesses.

Mammography BR3D Phantom For Tomosynthesis and Breast CTk Model 020 Benefits ?Tests Tomosynthesis and Breast Computed Tomography ?More representative than standard homogenous phantoms ?Complex background provides greater challenge for target detection ?Slab configurations provides range of thicknesses with or without targets The CIRS Model 020 BR3D Mammography Phantom was designed to assess detectability of various size lesions within a tissue equivalent, complex, heterogeneous background. This phantom provides more realistic challenges for standard screen and FFDM mammography systems as well as Tomosynthesis and breast Computed Tomography. The phantom consists of a set of six (6) slabs made of heterogeneous breast equivalent material that exhibits characteristics of real breast tissue and demonstrates how underlying targets can be obscured by varying glandularity. Each slab contains two tissue equivalent materials mimicking 100% adipose and gland tissues “swirled?together in a approximate 50/50 ratio by weight. One of the slabs contains an assortment of micro-calcifications, fibrils and masses. Each semicircular shaped slab measures 100 (H) x 180 (L) x 10 mm (T). Each slab, with its unique swirl pattern, provides varying backgrounds when arranged in multiple combinations and thicknesses.